				|  |  4 digit V / A/W Meter,display the Voltage(Vrms, Vpeak, Vmax., Vmin)、Current (Irms, Ipeak, Imax., Imin.)、Watt, Voltampere (VA)、requency、Crest Factor、Power Factor、Total Harmonic Distortion of Voltage (VTHD), Voltage Harmonic(VH)、Total Harmonic Distortion of  Current(ITHD), Current Harmonic(IH) 
  CC, Linear CC, CR, CV, CP and AC Rectifier Load mode 
  Crest factor range : 1.414~5.0 
  Power factor(PF) range : 0~1 lead or(-1~0)lag 
  Built-in function test modes include UPS Efficiency, PV Inverter Efficiency, UPS Back-up time, Battery Discharge time, UPS transfer time, Fuse/Breaker Trip/Non-Trip, Short circuit , OCP, OPP test modes 
  Turbo mode is able to increase to 2 times the current  and power of electronic load in a short period which is the most suitable for Fuse / Breaker test and short circuit, OCP, OPP test of AC power supply 
  Time measurement can be applied to batteries, UPS, fuses and circuit breakers and other tests 
  Three units parallel up to 11250W and three-phase △ or Y load connection can be synchronized control by one master unit 
  Frequency Range : DC, 40~440Hz 
  Voltage and current monitoring 
  Can be controlled by external voltage for CC, Linear CC, CR, CV, CP operating modes 
  Protection against V, I, W, and ℃ 
  Optional interface:GPIB、RS232、USB、LAN 
  The most complete measurement capabilities 
 32702 Series AC & DC electronic load built-in 16-bit A/D and DSP precision measurement circuit, provides accurate measurements, measurement items have Vrms, Arms, Watt, VA, CF, PF, THD, VTHD, ITHD, Ipeak, Amax, Amin, Vmax, and VminIn addition to these measurement functions, it also provides time measurement,products such as UPS, fuses and circuit breakers etc. trip or blow time and transfer time for Off-line UPS
 
 
 |  |  |